Cybernetics V Series CY-miSAN-V Manual de instrucciones Pagina 18

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 190
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 17
18 Setting Up the miSAN
Cybernetics UM-MV-86-B1-0801
Installing the Hardware Components
Rackmount Installation
The rackmount installation requires a 2U space in your rack. Follow the instructions
included in the rackmount kit.
Parallel SCSI
Host systems that will transmit commands and data via a directly-connected SCSI inter-
face to the miSAN-V-Series should have the host SCSI bus adapter installed and config-
ured.
Connecting the Cables
Parallel SCSI
The miSAN-V-Series includes two installed VHDCI 68-pin LVD ports. Each parallel SCSI
port is terminated internally. The port marked “host” is an Ultra160 LVD which is factory-
set to connect to an initiator (host system). The port marked “Reserved” or “Unused” is
used for the internal tape drive and should not be connected to by the user. The miSAN-
V-Series may not function properly if any device is attached to the reserved port..
Figure 2-1 shows the rear view of a typical miSAN-V-Series.
When attaching SCSI cables to the miSAN-V-Series, make sure the
host is connected to the appropriately labeled SCSI port.
Figure 2-1 miSAN-V-Series Rear Components
AC Power
Receptacles
iSCSI Network Ports
(RJ-45 Ethernet)
ETH2
ETH0
ETH1
Network Reset Button Hole
SCSI Ports (VHDCI
Management LAN Por
t
(RJ-45 Ethernet)
HOST RESERVED
Vista de pagina 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 189 190

Comentarios a estos manuales

Sin comentarios